Skip to content

Compare products

EasyT

EasyT

Non-compliant PTCA balloon, 21 atm rated burst pressure.

Learn more
OPN NC catheter hub

OPN NC

Super high-pressure PTCA balloon, 35 atm rated burst pressure.

Learn more
BioMime sirolimus-eluting coronary stent system

BioMime sirolimus-eluting coronary stent system

Sirolimus-eluting coronary stent system with 65 µm struts.

Learn more

Manufacturer

SIS Medical

SIS Medical

Meril

Model

EasyT

OPN NC

BioMime

Category

Coronary Intervention

Coronary Intervention

Coronary Intervention

Purchase

By quotation

By quotation

By quotation

Warranty

Not listed

Not listed

Not listed

Type

Non-compliant high-pressure PTCA dilatation catheter

Super-high pressure non-compliant PTCA dilatation catheter, twin-wall (balloon-in-balloon) design

Not listed

Balloon diameters

1.50, 2.00, 2.50, 3.00, 3.50, 4.00, 4.50 mm

1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5 mm

Not listed

Balloon lengths

6, 10, 15, 20 mm (all diameters); 25, 30 mm (2.00–4.50 mm)

10, 15, 20 mm

Not listed

Nominal pressure

10 atm (1.5–2.5 mm); 12 atm (3.0–4.5 mm)

10 atm

Not listed

Rated burst pressure

21 atm

35 atm

Not listed

Guiding catheter / guidewire

5F guiding catheter; 0.014" (0.36 mm) guidewire

Not listed

Not listed

Usable catheter length

140 cm

140 cm

Not listed

Coating

Hydrophilic (1.5–2.5 mm); hydrophobic (3.0–4.5 mm)

Not listed

Not listed

Markers

Dual Pt/Ir markers; tight trifold (1.5 mm bi-fold)

Not listed

Not listed

Regulatory

CE marked; not approved for sale in the USA; Swiss made

CE marked; FDA cleared

Not listed

Minimum guiding catheter

Not listed

6F (1.5–3.5 mm); 7F (4.0–4.5 mm)

Not listed

Guidewire

Not listed

0.014" (0.36 mm)

Not listed

Coating / markers

Not listed

Hydrophobic coating; dual Pt/Ir markers

Not listed

Required inflation device

Not listed

High-pressure inflation device rated to at least 35 atm

Not listed

Drug

Not listed

Not listed

Sirolimus, 1.25 µg/mm²

Polymer

Not listed

Not listed

PLLA and PLGA (biodegradable + biocompatible), 2 µm thickness

Stent material

Not listed

Not listed

Cobalt chromium L605

Strut thickness

Not listed

Not listed

65 µm

Stent architecture

Not listed

Not listed

Hybrid cell design (closed cells at ends, open cells in middle) with non-linear links

Diameters

Not listed

Not listed

2.00, 2.25, 2.50, 2.75, 3.00, 3.50, 4.00, 4.50 mm

Lengths

Not listed

Not listed

8, 13, 16, 19, 24, 29, 32, 37, 40, 44, 48 mm (8 mm not in 2.00 mm diameter)

Delivery system

Not listed

Not listed

Rapid exchange; 0.016" tip entry profile

Balloon overhang

Not listed

Not listed

Less than 0.5 mm